12/24VDC - 50/25A High Power Hall Effect Sync Control Box - 2 Channel- Wireless Remote
Skip to product information
1 of 6

12/24VDC - 50/25A High Power Hall Effect Sync Control Box - 2 Channel- Wireless Remote

12/24VDC - 50/25A High Power Hall Effect Sync Control Box - 2 Channel- Wireless Remote

Model: PA-CB41-2-12V24V

Low stock
Ships within 24 hours
Volume Discount
1-6 units $282.99 CAD
7-9 units $268.99 CAD
10-19 units $254.99 CAD
20+ units $226.99 CAD
Regular price $282.99 CAD
Regular price Sale price $282.99 CAD
Sale Sold out
  • Linear Actuator Calculator
  • Get Free Actuator Guide
  • Replacement chart
Advanced Performance
Advanced Performance
Wireless Convenience
Wireless Convenience
Smart Features
Smart Features
Effortless Integration
Effortless Integration
View full details
Description
PA-CB41-2-12V24V Specifications

The PA-CB41-2-12V24V is Progressive Automations’ most advanced high-current control box for synchronizing two Hall Effect Linear Actuators. It supports both 12VDC and 24VDC systems with plug-and-play compatibility for our Linear Actuators, Power Supplies, and Wiring Kits.

This actuator control solution features a self-learning procedure that allows pairing with a wide range of actuators within the supported range. Engineered for next-generation actuator control, it improves performance with higher power output, longer duty cycles, and faster wireless response. User experience is enhanced through simplified setup, an upgraded 4-button remote, and onboard indicators. Advanced safety systems actively protect your actuator setup by maintaining precise synchronization and automatically preventing damage from wiring faults, incorrect voltage, excessive loads, or overuse—ensuring smoother operation, longer component life, and reliable performance in demanding applications. 

Connectivity: Plug-and-play with all Heavy-Duty Hall Effect Linear Actuators and Power Supplies, with the appropriate wiring harness selected (sold separately). See the Compatibility section and Datasheet for more details. Please select one based on your configuration needs. 

Important: This control box does not come with a wiring harness. Be sure to check your setup requirements, as the harness may need to be purchased separately.

Overview
PA-CB41-2-12V24V Specifications

The PA-CB41-2-12V24V is Progressive Automations’ most advanced high-current control box for synchronizing two Hall Effect Linear Actuators. It supports both 12VDC and 24VDC systems with plug-and-play compatibility for our Linear Actuators, Power Supplies, and Wiring Kits.

This actuator control solution features a self-learning procedure that allows pairing with a wide range of actuators within the supported range. Engineered for next-generation actuator control, it improves performance with higher power output, longer duty cycles, and faster wireless response. User experience is enhanced through simplified setup, an upgraded 4-button remote, and onboard indicators. Advanced safety systems actively protect your actuator setup by maintaining precise synchronization and automatically preventing damage from wiring faults, incorrect voltage, excessive loads, or overuse—ensuring smoother operation, longer component life, and reliable performance in demanding applications. 

Connectivity: Plug-and-play with all Heavy-Duty Hall Effect Linear Actuators and Power Supplies, with the appropriate wiring harness selected (sold separately). See the Compatibility section and Datasheet for more details. Please select one based on your configuration needs. 

Important: This control box does not come with a wiring harness. Be sure to check your setup requirements, as the harness may need to be purchased separately.

Product Specifications
FunctionSynchronized control of heavy duty Hall effect linear actuators
Number of Channels2
Input Voltage12 VDC or 24 VDC
Output Voltage12 VDC or 24 VDC
Current Capacity25 A per channel at 12 VDC
12.5 A per channel at 24 VDC
Total Power Output600 W total
300 W per channel
Duty Cycle25%, up to max 5 minutes continuous operation
Power ManagementAutomatic power saving mode
Wake Response TimeInstant wake up with single press, 100 ms response time
Operating Temperature14°F to 122°F (-10°C to 50°C)
Protection and Safety Features
  • Out of synchronization
  • Output short circuit
  • Overcurrent / overload
  • Over duty cycle
  • Out of range input voltage
  • Reverse input voltage
System IndicatorsDual LED indicators, audible buzzer, onboard push button
Housing MaterialABS Plastic
Housing ColorBlack with blue accents
Dimensions7.95" x 5.20" x 1.47"
Unit Weight0.75 lbs
Included ComponentsControl box and RT-40 wireless remote with battery
18 Months
Control and Interface Options
Power and Cabling
Control Boxes Compatibility
Technical Information

Following a set of standards is crucial for businesses to ensure their products and services can meet a level of quality that promotes customer satisfaction. At Progressive Automations, we aim for nothing but the best for our customers and strive toward continual improvements. Because of this, we are excited to announce that Progressive Automations is now ISO 9001:2015 certified!

Quality Assured

Data Sheets

PA-CB41-2-12V24V Data Sheet

Data Sheet for PA-CB41-2-12V24V

View
Video & Articles
Videos
Related blog articles:
Photo of a trapdoor with hinged door

How To Automate Your Trap Door Application

Nathan Bong

How To Automate Your Trap Door Application Automated trap doors improve safety, convenience, and ...

Learn more : How To Automate Your Trap Door Application
Comparing Technologies: Optical Encoders VS Hall Effect Sensors

Comparing Technologies: Optical Encoders VS Hall Effect Sensors

Nathan Bong

When properly implemented, positional feedback can allow multiple actuators to move together sync...

Learn more : Comparing Technologies: Optical Encoders VS Hall Effect Sensors
Introducing The PA-CB31 and PA-CB40 Actuator Control Boxes

Introducing The PA-CB31 and PA-CB40 Actuator Control Boxes

Nathan Bong

We’re excited to announce the release of two new additions to our growing lineup of actuator cont...

Learn more : Introducing The PA-CB31 and PA-CB40 Actuator Control Boxes
The Pros & Cons of Feedback Devices

The Pros & Cons of Feedback Devices

Temir Baimukhametov

DC motors are widely used both in industrial applications and at home for personal projects. One ...

Learn more : The Pros & Cons of Feedback Devices
Photo of the prototype system for automated Phantom BBQ

Sponsorship: Dr. Decks Phantom Bbq Progress Report

Adam Morissette

Dr. Decks has been one of our most valued customers for a long time and we have worked together o...

Learn more : Sponsorship: Dr. Decks Phantom Bbq Progress Report
FAQ
How does the self-learning synchronization process work for pairing two Hall Effect actuators with the PA-CB40 control box?

During the initial setup, the PA-CB40 is required to go through its 1st hard reset procedure, which is also when the self-learning control system actively gathers stroke length information as the actuators fully extend and retract. A short “teach” cycle will be for counting Hall effect feedback pulses to map stroke length and speed. After completing this Hall effect actuator pairing, the controller trims motion in real time so both units start, travel, and stop together synchronously—even under uneven load.

What types of actuators and power supplies are compatible with the PA-CB40, and how do I choose the correct wiring harness?

Hall Effect feedback and brushed 12 VDC (12.5A) or 24 VDC (6.25A) motors are required for actuator compatibility, while being within the current and voltage ratings. Choose power supplies that output the same voltage as the operating voltage of the chosen actuators and can handle the total current draw of both actuators. Select the PA-CB40 wiring harness that matches your actuator connector (e.g., Molex Mini-Fit Jr. or flying leads with ring/spade lugs) and wire gauge appropriate to your current draw and cable length requirements.

What are the built-in safety protections in the PA-CB40, and how do they respond to faults like overload or short circuit?

The PA-CB control box safety features include out-of-synchronization, output short circuit, over-duty-cycle, out-of-range input voltage, reverse input voltage, and overcurrent/overload protection. The controller monitors output current draw and will halt all control box actions to cancel any outstanding commands when the output draws too much current, such as during an overload or short circuit. 

Can I use the upgraded 4-button remote for custom positioning or simultaneous movement, and how is it configured?

Yes, a 4-button actuator remote is included with the PA-CB40 to access Up, Down, Stop, and Programming Mode for synchronized dual actuator operation. The configuration process for all the different mode options is fairly extensive and covered in full detail starting at page 9 of our PA-CB40 control box data sheet

What are the key differences in performance between 12 VDC and 24 VDC setups using this control box?

At the same mechanical load, a 24 VDC system draws roughly half the current of a 12 VDC system, reducing voltage drop, wiring losses, and heat in the controller. Actual speed/force is determined by the actuator model; the PA-CB40 logic and sync performance are identical for either voltage configuration. 

Recently Viewed